High accuracy injection circuit for pixel-level calibration of readout electronics
Contributo in Atti di convegno
Data di Pubblicazione:
2011
Citazione:
(2011). High accuracy injection circuit for pixel-level calibration of readout electronics . Retrieved from http://hdl.handle.net/10446/120956
Abstract:
This work will discuss the design of a high-linearity, low dispersion injection circuit to be used for pixel-level calibration of detector readout electronics. The circuit allows for precise analog test of the pixel cell units already at the chip level, when no sensor is connected. Moreover, it provides a simple means for calibration of readout electronics once the detector has been connected to the chip. The circuit discussed here will be part of the readout chip for the DEPFET Sensor with Signal Compression which is currently under development for application at the European XFEL facility. Since two options for the detector readout are currently under investigation, two injection circuit architectures have been designed. The aim of the paper is to discuss the design guidelines for the calibration circuit and to present the relevant simulation results of the developed system which will be implemented in a 130 nm CMOS technology.
Tipologia CRIS:
1.4.01 Contributi in atti di convegno - Conference presentations
Elenco autori:
Manghisoni, Massimo; Quartieri, Emanuele; Ratti, L.; Traversi, Gianluca
Link alla scheda completa:
Titolo del libro:
2010 IEEE Nuclear Science Symposium, Medical Imaging Conference, NSS/MIC 2010 and 17th International Workshop on Room-Temperature Semiconductor X-ray and Gamma-ray Detectors, RTSD 2010
Pubblicato in: