Smooth Moves: Comparing Log Dimensionless Jerk Metrics from Body Center of Mass Trajectory and Wearable Sensor Acceleration During Walking

Articolo
Data di Pubblicazione:
2025
Citazione:
(2025). Smooth Moves: Comparing Log Dimensionless Jerk Metrics from Body Center of Mass Trajectory and Wearable Sensor Acceleration During Walking [journal article - articolo]. In SENSORS. Retrieved from https://hdl.handle.net/10446/310125
Abstract:
Movement smoothness is a critical metric for evaluating motor control and sensorimotor impairments, with increasing relevance in neurorehabilitation and everyday functional assessments. This study investigates the correlation between two smoothness metrics (Log Dimensionless Jerk): LDLJV, derived from body center of mass (BCoM) trajectories using a gold-standard stereophotogrammetric system, and LDLJA, calculated from acceleration data recorded via an inertial measurement unit (IMU) placed at the L1–L2 level. Ten healthy adults (six men and four women; height: 1.71 ± 0.08 m; body mass: 68.2 ± 10.2 kg; age: 34.5 ± 8.5 years) walked on a treadmill at seven different speeds, with stride-specific data analyzed to compute smoothness indices for three anatomical components (antero-posterior, medio-lateral, cranio-caudal). Concordance between the metrics was evaluated using Bland–Altman analysis, Spearman’s correlation, and the mean absolute percentage error. The results revealed weak correlations and substantial biases across all components and speeds, reflecting inherent differences between IMU- and BCoM-derived data. Correcting biases improved alignment but did not eliminate discrepancies. The findings highlight that LDLJA captures only localized trunk accelerations, whereas BCoM-derived LDLJV approximates whole-body dynamics, making direct substitution infeasible. This study emphasizes the need for careful interpretation of IMU-based metrics and contributes to refining their application in real-world gait analyses.
Tipologia CRIS:
1.1.01 Articoli/Saggi in rivista - Journal Articles/Essays
Elenco autori:
Brasiliano, Paolo; Pavei, Gaspare; Bergamini, Elena
Autori di Ateneo:
BERGAMINI Elena
Link alla scheda completa:
https://aisberg.unibg.it/handle/10446/310125
Link al Full Text:
https://aisberg.unibg.it/retrieve/handle/10446/310125/907280/2025_Brasiliano_Sensors_Smoothness.pdf
Pubblicato in:
SENSORS
Journal
Progetto:
Contactless And ReliAble MovEment anaLysis with miLlimeter-waves rAdars