Monolithic active pixel sensor development for the upgrade of the ALICE inner tracking system

Academic Article
Publication Date:
2013
Short description:
(2013). Monolithic active pixel sensor development for the upgrade of the ALICE inner tracking system [journal article - articolo]. In JOURNAL OF INSTRUMENTATION. Retrieved from http://hdl.handle.net/10446/187042
abstract:
ALICE plans an upgrade of its Inner Tracking System for 2018. The development of a monolithic active pixel sensor for this upgrade is described. The TowerJazz 180 nm CMOS imaging sensor process has been chosen as it is possible to use full CMOS in the pixel due to the offering of a deep pwell and also to use different starting materials. The ALPIDE development is an alternative to approaches based on a rolling shutter architecture, and aims to reduce power consumption and integration time by an order of magnitude below the ALICE specifications, which would be quite beneficial in terms of material budget and background. The approach is based on an in-pixel binary front-end combined with a hit-driven architecture. Several prototypes have already been designed, submitted for fabrication and some of them tested with X-ray sources and particles in a beam. Analog power consumption has been limited by optimizing the Q/C of the sensor using Explorer chips. Promising but preliminary first results have also been obtained with a prototype ALPIDE. Radiation tolerance up to the ALICE requirements has also been verified.
Iris type:
1.1.01 Articoli/Saggi in rivista - Journal Articles/Essays
List of contributors:
Aglieri, G.; Cavicchioli, C.; Chalmet, P. L.; Chanlek, N.; Collu, A.; Giubilato, Piero; Hillemanns, H.; Junique, A.; Keil, M.; Kim, D.; Kim, J.; Kugathasan, T.; Lattuca, A.; Mager, M.; Marin Tobon, C. A.; Marras, D.; Martinengo, P.; Mattiazzo, Serena; Mazza, G.; Mugnier, H.; Musa, L.; Pantano, D.; Puggioni, C.; Rousset, J.; Reidt, F.; Riedler, P.; Siddhanta, S.; Snoeys, W.; Usai, G.; Van Hoorne, J. W.; Yangm, P.; Yi, J.
Handle:
https://aisberg.unibg.it/handle/10446/187042
Full Text:
https://aisberg.unibg.it/retrieve/handle/10446/187042/431039/G_Aglieri_2013_J._Inst._8_C12041.pdf
Published in:
JOURNAL OF INSTRUMENTATION
Journal
  • Research

Research

Concepts


Settore FIS/01 - Fisica Sperimentale
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.4.3.0