3D Scanning Procedure for the Evaluation of Lymphedema of Upper Limbs Using Low-Cost Technology: A Preliminary Study

Contributo in Atti di convegno
Data di Pubblicazione:
2020
Citazione:
(2020). 3D Scanning Procedure for the Evaluation of Lymphedema of Upper Limbs Using Low-Cost Technology: A Preliminary Study . Retrieved from http://hdl.handle.net/10446/153246
Abstract:
This research work presents a preliminary study for the assessment of lymphedema using low-cost 3D scanning and modelling technology. The aim is to develop a methodology to measure the anatomical key features of the upper limbs lymphedema using a 3D scanning technology and an ad-hoc developed application, named Lym 3DLab. The application is able to automatically measure both perimeters of cross sections and volumes of arm segments for medical evaluation and design of compression stockings using the upper limb polygonal mesh. The scanning procedure is based on a Microsoft Kinect v1 as scanner and the low-cost Skanect tool, which creates the polygonal mesh of the 3D acquisition. Lym 3DLab has been developed using open-source Software Development Kits, such as Qt and Visualization Toolkit. The acquired volumes have been compared with the water displacement method, which is considered the gold standard for measuring volumes of limbs affected by lymphedema. A preliminary test has been performed to compare volumes measured using the developed procedure with the gold standard. Five volunteers have been involved who are not affected by lymphedema. The arm volume measured with water displacement have been compared with the volume computed using 3D model of arm in Lym 3DLab. The range of differences is between −6,75 cm3 and 9,40 cm3. Reached results are the base for planning further test with a large number of patients affected by lymphedema in collaboration with a hospital.
Tipologia CRIS:
1.4.01 Contributi in atti di convegno - Conference presentations
Elenco autori:
Vitali, Andrea; Regazzoni, Daniele; Rizzi, Caterina; Molinero, Guido
Autori di Ateneo:
REGAZZONI Daniele
RIZZI Caterina
VITALI Andrea
Link alla scheda completa:
https://aisberg.unibg.it/handle/10446/153246
Titolo del libro:
Design Tools and Methods in Industrial Engineering: Proceedings of the International Conference on Design Tools and Methods in Industrial Engineering, ADM 2019, September 9–10, 2019, Modena, Italy
Pubblicato in:
LECTURE NOTES IN MECHANICAL ENGINEERING
Series
  • Ricerca

Ricerca

Settori


Settore ING-IND/15 - Disegno e Metodi dell'Ingegneria Industriale