In-plane capacity of existing post-WWII beam-and-clay block floor systems

Articolo
Data di Pubblicazione:
2022
Citazione:
(2022). In-plane capacity of existing post-WWII beam-and-clay block floor systems [journal article - articolo]. In BULLETIN OF EARTHQUAKE ENGINEERING. Retrieved from http://hdl.handle.net/10446/202021
Abstract:
A growing attention has been paid to the deep renovation of RC buildings, particularly focusing on their structural vulnerability and on the development of retrofit strategies; however, the issue of the in-plane diaphragm action and the capacity of existing floors has rarely been addressed. Although floor capacity does not seem critical for the seismic capac- ity of existing structures, commonly affected by greater vulnerabilities, it may become crit- ical when an additional lateral force resisting system is introduced. This paper investigates the in-plane capacity of beam and hollow-clay-block floor system, typical of the European post-WWII RC buildings. Considering the diaphragm action as associated with an in-plane tied-arch mechanism developing within the floor thickness, the main failure mechanisms are discussed, and some simplified equations are provided to preliminary estimate the max- imum capacity of floors. Experimental and numerical analyses are than carried out to vali- date the simplified analytical model. The relevant influence of possible staircase openings on the in-plane load paths and on diaphragm flexibility and capacity are also considered. Finally, the influence of the floor capacity on the seismic vulnerability assessment and in the conceptual design of a seismic retrofit intervention is discussed. This preliminary study shows that only some of the beam-and-block floor systems have a reliable in-plane capac- ity, while other typologies cannot serve as floor diaphragms. When the diaphragm action can be relied upon, the diaphragms often exhibit a fairly stiff behaviour up to a brittle fail- ure, which is commonly associated with the ultimate capacity at the tied-arch supports
Tipologia CRIS:
1.1.01 Articoli/Saggi in rivista - Journal Articles/Essays
Elenco autori:
Marini, Alessandra; Belleri, Andrea; Passoni, Chiara; Feroldi, Francesca; Giuriani, Ezio
Autori di Ateneo:
BELLERI Andrea
MARINI Alessandra
PASSONI Chiara
Link alla scheda completa:
https://aisberg.unibg.it/handle/10446/202021
Link al Full Text:
https://aisberg.unibg.it/retrieve/handle/10446/202021/470880/IJ33%20-%20Pub%20-%20Floor%20diaphragms%20-%20BEE.pdf
Pubblicato in:
BULLETIN OF EARTHQUAKE ENGINEERING
Journal
  • Ricerca

Ricerca

Settori


Settore ICAR/09 - Tecnica delle Costruzioni
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.6.1.0