A mixed-signal processor for X-ray spectrometry and tracking in the GAPS experiment

Academic Article
Publication Date:
2023
Short description:
(2023). A mixed-signal processor for X-ray spectrometry and tracking in the GAPS experiment [journal article - articolo]. In NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. Retrieved from https://hdl.handle.net/10446/233871
abstract:
This paper reports the design and experimental results from the characterization of an integrated circuit developed for the readout of the X-ray spectrometer and tracking system of the General AntiParticle Spectrometer (GAPS) balloon mission. GAPS will search for an indirect signature of dark matter through the detection of low-energy (<0.25 GeV/n) cosmic-ray antiprotons, antideuterons and antihelium nuclei. The ASIC, named SLIDER32 (32 channels Si-LI DEtector Readout ASIC), was fabricated in a 180 nm CMOS technology and is comprised of 32 analog readout channels, an 11-bit SAR ADC and a digital back-end section which is responsible for defining channel settings and for sending digital information to the data acquisition system. The core of the ASIC is a low-noise analog channel implementing a dynamic signal compression which makes the chip suitable for resolving both X-rays in the range of 20 to 100 keV and charged particles with energy deposition of up to 100 MeV. It features an energy resolution of 4 keV FWHM in the 20–100 keV range with a 40 pF detector capacitance, to clearly distinguish X-rays from antiprotonic or antideuteronic exotic atoms. The readout electronics of the ASIC will run at a temperature of about –40 °C, complying with a detector leakage current of the order of 5–10 nA per strip.
Iris type:
1.1.01 Articoli/Saggi in rivista - Journal Articles/Essays
List of contributors:
Re, Valerio; Ghislotti, Luca; Lazzaroni, Paolo; Manghisoni, Massimo; Riceputi, Elisa; Ratti, Lodovico; Boezio, Mirko; Zampa, Gianluigi; Fabris, Lorenzo
Authors of the University:
LAZZARONI Paolo
MANGHISONI Massimo
RE Valerio
RICEPUTI Elisa
Handle:
https://aisberg.unibg.it/handle/10446/233871
Published in:
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT
Journal
  • Research

Research

Concepts


Settore ING-INF/01 - Elettronica
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.4.3.0