Skip to Main Content (Press Enter)

Logo UNIBG
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze

UNI-FIND
Logo UNIBG

|

UNI-FIND

unibg.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze
  1. Pubblicazioni

Heavily irradiated 65-nm readout chip with asynchronous channels for future pixel detectors

Articolo
Data di Pubblicazione:
2018
Citazione:
(2018). Heavily irradiated 65-nm readout chip with asynchronous channels for future pixel detectors [journal article - articolo]. In IEEE TRANSACTIONS ON NUCLEAR SCIENCE. Retrieved from http://hdl.handle.net/10446/130890
Abstract:
This paper discusses the main results relevant to the characterization of an analog front-end processor designed in view of experiments with unprecedented particle rates and radiation levels at the high-luminosity Large Hadron Collider (HL-LHC). The front-end channel presented in this paper is part of the CHIPIX65-FE0 prototype, a readout application-specified integrated circuit designed in a 65-nm CMOS technology in the frame of the CERN RD53 collaboration. The prototype integrates a 64 × 64 pixel matrix, divided into two 32 × 64 submatrices, featuring squared pixels with 50- μm pitch, embodying two analog front-end architectures based on synchronous and asynchronous hit discriminators. This paper is focused on the characterization of the array with asynchronous channels, before and after exposure to ionizing doses up to 630 Mrad(SiO2) of X-rays. The analog chain takes a per-channel area close to 1000 μm2, with a power dissipation of around 5 μW. The mean value of the equivalent noise charge, not significantly affected by radiation, is close to 100 electrons with no sensor connected to the front end. The threshold dispersion before irradiation is 55 electrons, for a tuned threshold of 600 electrons, with a moderate increase after irradiation. In-pixel analog-to-digital conversion, based on the time-over-threshold technique, is not appreciably influenced by the radiation as well. The assessed performance guarantees sub-1000 electrons stable threshold operations, which is a mandatory feature for highly efficient readout chips at the HL-LHC.
Tipologia CRIS:
1.1.01 Articoli/Saggi in rivista - Journal Articles/Essays
Elenco autori:
Gaioni, Luigi; DE CANIO, Francesco; Manghisoni, Massimo; Ratti, L.; Re, Valerio; Sonzogni, Mauro; Traversi, Gianluca
Autori di Ateneo:
GAIONI Luigi
MANGHISONI Massimo
RE Valerio
TRAVERSI Gianluca
Link alla scheda completa:
https://aisberg.unibg.it/handle/10446/130890
Pubblicato in:
IEEE TRANSACTIONS ON NUCLEAR SCIENCE
Journal
  • Ricerca

Ricerca

Settori


Settore ING-INF/01 - Elettronica
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.1.3.0